Teledyne Stud Sensor 452 Manual de usuario

Busca en linea o descarga Manual de usuario para De medición, control y control Teledyne Stud Sensor 452. Teledyne Stud Sensor 452 User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 30
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
MODEL 452
PROCESS OZONE SENSOR
©Teledyne Instruments
Advanced Pollution Instrumentation Division
(T-API)
9480 Carroll Park Drive
San Diego, CA 92121-5201
TOLL-FREE: 800-324-5190
TEL: 858-657-9800
FAX: 858-657-9816
WEB SITE: www.teledyne-api.com
Vista de pagina 0
1 2 3 4 5 6 ... 29 30

Indice de contenidos

Pagina 1 - MODEL 452

MODEL 452 PROCESS OZONE SENSOR ©Teledyne Instruments Advanced Pollution Instrumentation Division (T-API) 9480 Carroll Park Drive San Diego, CA 92121-

Pagina 2 - SAFETY MESSAGES

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 1-1 1 Product Descriptions 1.1 M452 Process Ozone Sensor The Teledyne API M452 is a

Pagina 3

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 1-2 INTENTIONALLY BLANK

Pagina 4 - TABLE OF CONTENTS

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 2-1 2 Specifications Note: All specifications contained herein are subject to change

Pagina 5

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 2-2 2.2 Performance Specifications Accuracy: Repeatability: 1% of Full Scale. 1% of

Pagina 6 - LIST OF TABLES

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 2-3 2.6 Pressure Drop Figure 2-2 below shows the approximate pressure drop from the

Pagina 7

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 2-4 2.7 Options The M452 is available with the following options: 2.7.1 AC Power Ada

Pagina 8 - WARRANTY POLICY

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 3-1 3 Theory of Operation The detection of ozone molecules is based on absorption of

Pagina 9

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 3-2 The intensity of light is converted into a voltage by the detector/preamp module

Pagina 10 - 1 Product Descriptions

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 4-1 4 Installation 4.1 Unpacking Upon receiving the M452 please verify that no appar

Pagina 11 - INTENTIONALLY BLANK

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 4-2 Analog Out -Analog Out +Power Common+15 Volt Supply+15 Volt SupplyDigital In #1D

Pagina 12 - 2 Specifications

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E i SAFETY MESSAGES NOTE The M452 contains no user serviceable parts. CAUTION There

Pagina 13 - 2.5 Calibration Reference

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 4-3 4.3.2 Analog Output The analog output is a 0-5 volt signal representing the ozon

Pagina 14 - 2.6 Pressure Drop

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 4-4 4.3.4 Status Outputs The M452 has four digital status outputs for indicating err

Pagina 15 - 2.7 Options

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 4-5 4.3.5 RS232/485 Interface The M452 features a bi-directional digital serial inte

Pagina 16 - 3 Theory of Operation

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 4-6 4.4 Gas Connections Gas connections to the M452 are made using ¼” compression tu

Pagina 17

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 4-7 4.5 Start-Up and Calibration Procedure 1. Verify that the proper electrical con

Pagina 19 - 4.3.1 Power Supply

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 5-1 5 Sensor and System Troubleshooting This chapter gives guidelines for diagnosing

Pagina 20 - 4.3.3 Zero Calibration Input

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 5-2 5.2 Status Outputs Table 5-1 below describes the function of the status outputs.

Pagina 21 - 4.3.4 Status Outputs

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 5-3 5.4 Invalid Reading The normal state for the Invalid Reading output is OFF. If

Pagina 22 - 4.3.5 RS232/485 Interface

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 5-4 5.6 Cell Dirty The normal state for the Cell Dirty output is OFF. If this outpu

Pagina 24

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E 5-5 INTENTIONALLY BLANK

Pagina 25

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E iii TABLE OF CONTENTS SAFETY MESSAGES...

Pagina 26 - Troubleshooting

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E iv 5 SENSOR AND SYSTEM TROUBLESHOOTING ...5-1 5.1 STATUS LED’S...

Pagina 27 - 5.3 Sensor O.K

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E v LIST OF FIGURES FIGURE 2-1: M452A HIGH PURITY OZONE SENSOR...

Pagina 29 - 5.6 Cell Dirty

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E vii WARRANTY POLICY ADVANCED POLLUTION INSTRUMENTATION DIVISION 02024c Prior to ship

Pagina 30

Teledyne API M452 Ozone Sensor Instruction Manual, 02852, Rev. E viii THE WARRANTIES SET FORTH IN THIS SECTION AND THE REMEDIES THEREFORE ARE EXCLUSI