Teledyne 201A Manual de usuario

Busca en linea o descarga Manual de usuario para De medición, control y control Teledyne 201A. Teledyne 201A User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 31
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
MANUAL ADDENDUM
MODEL 201A
AMMONIA ANALYZER
TELEDYNE ADVANCED POLLUTION INSTRUMENTATION
(T-API)
9480 CARROLL PARK DRIVE
SAN DIEGO, CA 92121-5201
TOLL-FREE: 800-324-5190
FAX: 858-657-9816
TEL: 858-657-9800
WEB SITE:
www.teledyne-api.com
04689
REV. B1
Copyright 2005 T-API Inc.
12 September, 2005
Vista de pagina 0
1 2 3 4 5 6 ... 30 31

Indice de contenidos

Pagina 1 - AMMONIA ANALYZER

MANUAL ADDENDUM MODEL 201A AMMONIA ANALYZER TELEDYNE ADVANCED POLLUTION INSTRUMENTATION (T-API) 9480 CARROLL PARK DRIVE SAN DIEGO, CA 92121

Pagina 2 - SAFETY MESSAGES

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 1.2 M201A Analyzer Specifications Ranges 0-50 to 0-2000 ppb in 1 ppb increme

Pagina 3 - TABLE OF CONTENTS

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 2.0 CALIBRATION PROCEDURE Calibration of the M201A is done by first calibratin

Pagina 4 - LIST OF FIGURES

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 Table 2.1 - Zero Calibration Procedure - Zero Gas Through the Sample Port Ste

Pagina 5 - LIST OF TABLES

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 Table 2.3 - Span Calibration Procedure - Span Gas thru Sample Port Step No.

Pagina 6

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 2.1.1 Zero/Span Calibration with Z/S Valves or ECO Option The zero gas enters

Pagina 7 - 1.0 M201A AMMONIA ANALYZER

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 Table 2.5 - Enter the Expected Span Gas Concentrations Procedure Step No. Ac

Pagina 8

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 Table 2.6 - CALS - Span Cal Procedure - Gas from rear panel span gas inlet S

Pagina 9 - 1.1.2 Sample Filtration

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 2.1.3 NH3 Calibration Since the system efficiency is less than 100%, it is ne

Pagina 10

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 The instrument is now fully calibrated. 2.1.4 Channel Calibration Quality Af

Pagina 11 - 2.0 CALIBRATION PROCEDURE

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 3.0 MAINTENANCE SCHEDULE 3.1 M201A Maintenance Schedule The maintenance requi

Pagina 12

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 SAFETY MESSAGES Your safety and the safety of others is very important. We hav

Pagina 13

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 Table 3.2 – M501NH Converter Rebuild Parts List Part No. Description KIT0001

Pagina 14

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 3.3 AutoZero Flow Check Since the M201A is an ammonia analyzer, the flow thro

Pagina 15

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 Figure 1 - M201A Ammonia Analyzer – Block Diagram 21

Pagina 16

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 MODULEAIRZEROFROMSPAN02522 UMBILICAL CORDTO VACCUM PUMPPOWERUMBILICALTOCONVCON

Pagina 17 - 2.1.3 NH3 Calibration

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 Figure 3 - M201A Pneumatic Diagram Basic 23

Pagina 18

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 Figure 4 - M201A Pneumatic Diagram Z/S Option 24

Pagina 19 - 3.0 MAINTENANCE SCHEDULE

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 Figure 5 - M201A Pneumatic Diagram External Calibrator Option (ECO) 25

Pagina 20

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 Figure 6 – M501NH Converter Cartridge 26

Pagina 21 - 3.3 AutoZero Flow Check

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 27

Pagina 22

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 4.0 M201A SPARE PARTS LIST 000940400 Orifice, 4 mil, 80 cc, Rx Cell 0009406

Pagina 23 - Teledyne API Model 201A NH

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 TABLE OF CONTENTS SAFETY MESSAGES ...

Pagina 24

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 M201A Spare Parts List (cont.) 016810200 O3 Generator Assembly for M200A/200

Pagina 25

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 M201A Spare Parts List (cont.) KIT000129 Welded Moly, Cartridge only KIT0001

Pagina 26

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 LIST OF FIGURES FIGURE 1 - M201A AMMONIA ANALYZER – BLOCK DIAGRAM ...

Pagina 27

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 LIST OF TABLES TABLE 2.1 - ZERO CALIBRATION PROCEDURE - ZERO GAS THROUGH THE

Pagina 28

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 5

Pagina 29 - 4.0 M201A SPARE PARTS LIST

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 1.0 M201A AMMONIA ANALYZER This manual is to be used in conjunction with the

Pagina 30

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 converts some of the ammonia to NO, thus the TN channel data contains a small

Pagina 31

Teledyne API Model 201A NH3 Analyzer Instruction Manual, 04689, Rev. B1 Do NOT use copper tubing or fittings designed for household plumbing. Use ON

Comentarios a estos manuales